ABBV1 auto-bypass valve

● 22mm Angled Automatic Bypass Valve
● Reduces system noise
● Maintains an even system pressure
● Constant flow through the boiler

Product Code:
ABBV1

Compare

Description

The Tower ABBV1 should be fitted where a boiler bypass is required. Typically this is the case when a system is equipped with thermostatic radiator vaIves (TRV‘s), and to allow pump overrun operation after zone valves have closed down.

TRV’s slowly close down as each radiator raises the room temperature. To overcome Flow restriction as TRV’s close down, the ABBV1 is adjusted to the required set point. As the system resistance increases due to TRV’s closing, the ABBV1 allows the flow to Increase in order to maintain the required pre-set system differential pressure. The regulation provided will reduce system noise that can result from TRVs or zone valves closing, eliminate pump impeller wear that can result from high flow resistance and enhance the life of the boiler‘s heat exchanger by ensuring a minimum flow rate at all times.

Installation should be in a loop between flow and return after the pump. Ensure that the flow is in the direction of the arrow on the ABBV1 body. Rotate the adjustment head until the required setting number is visible, and lock the valve at that point by tightening the screw on top of the adjuster. Refer to the recommendations in the boiler instructions and the pressure /flow rates detailed below to decide which setting is required.

Features:
● High capacity flow up-to 50 litres per minute
● Wide differential pressure range 0.1 bar to 0.6 bar
● 22mm Compression fittings
● Reduces system noise
● Maintains an even system pressure
● Constant flow through the boiler
● Lockable set pressure

Product Code: ABBV1 (Angled 22mm Automatic Bypass valve)

ABBV1 & ABBV1ST Spec Sheet

Download