Regulates heating system differential pressure
High capacity flow up to 50 litres per minute
Differential pressure range 0.1 to 0.6 bar
22mm compression fitting
The Tower ABV should be fitted where a boiler bypass is required – typically this is the case when a system is equipped with thermostatic radiator valves (TRV’s), and to allow pump overrun operation after zone valves have closed down.
TRV’s slowly close down as each radiator raises the room temperature. To overcomeflow restriction as TRV’s close down, the ABV is adjusted to the required set point. As the system resistance increases due to TRV’s closing, the ABV allows flow to increase, in order to maintain the required pre-set system differential pressure. The regulation provided will reduce system noise that can result from TRV’s or zone valves closing, eliminate pump impeller wear that can result from high flow resistance, and enhance the life of the boiler’s heat exchanger by ensuring minimum flow rate at all times.